Introduction . . .

This is a brand new blog, by a brand new blogger. However, some readers may recognize this blog's title, taken from a series of books of the same name. Unfortunately, time has a way of gradually making printed material all too quickly outdated -- especially these days -- and so, this blog was created partly as an attempt to address that issue.

As we move forward from here on-going efforts will be made to transfer selected content from the Better Microscopy books series into this new format, not only to provide to provide more effective distribution, but also as a means for making timely additions and overdue updates to that material. In addition, much previously unpublished material is now planned to be released, including high-resolution color images.

The current plan is to aim for a content mix that is both interesting and educational -- perhaps even inspiring -- and which will address the needs and interests of a wide range of user levels, from beginner to semi-professional. With more decades of Microscopy experience than I care to admit, I hope I will be able to contribute something to others in terms of both knowledge and enjoyment.

I hope you find something of interest in new undertaking as it takes shape and gain much from its content, now and well into the future!

Just beware of the occasional attempts at humor...

Thanks for visiting!


Monday, August 26, 2019

Finally — New Book Downloads (Free!)

The popular Better Microscopy Compendium Edition is now available for download as a set of .pdf files.

Previously, this book was an aggregation of four separate volumes, merged to maximize publishing economy for a printed format. However, at well over 300 pages (total) it seemed best to split the complete book into the original separate volumes, for easier downloading and/or online reading. 

Consequenlty, the downloads offered below (.pdf files) have been orgainzed as follows:

    Compendium Edition (Intro.) — F/R covers (art), basic Table of Contents... (6pp.)

    Volume I: Transmitted Light Microscopy — Full text with Combined Index. (104pp.)

    Volume II: Optical Contrast Techniques — Full text, with Index. (44pp.)

    The Practical Guide to Microscopes — Full text with tables. (98pp.)

    Notes on Microscopy — Original Notes collection and graphics. (56pp.)

    (Total of above downloads = 308pp.)  Just click the individual links to the .pdf files!

Note that since the download text retains the formatting for the original book page size (~7.5 x 9.6 in.) you may wish to adjust your printer settings to achieve a printed page output format most appropriate to your needs.

Also, note that while original page numbering has been retained, a few extraneous (blank/'filler') pages have been deleted, resulting in some numbering "gaps" within the separate volumes. If this bothers you, please feel free to restore these blank pages in your printouts. . . (lol)

Thank you!
* * * * * * * 

Monday, October 29, 2018

Secrets of the Leitz Heine — Part 3.

The saga of Leitz Heine "Secrets..." continues with this latest release – Part 3.

In this Part, we find that the iconic Heine Condenser can actually (and easily!) be fitted to many of the newest generation  (1980's) Leitz scopes. (Often referred to as "Wild-Leitz" scopes, because of the 1980's Wild-Leitz corporate merger.)

Leitz ceased production of their Heine condensers in the 1970's and no new version was ever made for the new scopes. So, if you have (or want) one of these scopes, and wish to mount a Heine on it, the methods in this Part may be your best bet!

Note that this Part continues the shift towards increased use of graphic illustrations, instead of lengthy descriptions.


Parts 1 and 2 of this series were released in an earlier post (October 22, 2018).

I hope you find this latest release useful and informative!

* * * * *

Monday, October 22, 2018

Secrets of the Leitz Heine Condenser — Part 2

Part 1 covered technical details of the famous Leitz Heine condenser and its use.

Part 2 extends this coverage to show how the Heine can easily be used with many non-Leitz scopes!

The attached .pdf file contains Part 2 plus an updated Part 1 (with minor revisions).


I hope you find this material interesting and useful!

* * * * *

Wednesday, October 10, 2018

Secrets of the Leitz Heine Condenser — Part 1

Here, finally, is the long-awaited release of current work on the Leitz Heine condenser. This Part discusses the basics of the condenser and its use.


As usual, the file is in ".pdf" format and should be easily viewable online, as well as also downloadable and printable, if desired. 

The next release is planned to cover detailed Heine application information and discuss means for adapting the Leitz units to other, more modern scopes! 

I hope you find this useful. . .


* * * * *

Sunday, July 1, 2018

Camera Coupling Methods (from Vol. III)

With this post we continue the incremental release of content from the 2016 edition of Volume III of the Better Microscopy book series.

This release is contains app Notes Nos. 10-13, discussing the most common forms of Optical Coupling Methods for a Camera to a Microscope. (This is a .pdf file of about 700KB, formatted for printing on US Standard Letter (8.5 x 11in) size, 18pp.)  


Depending upon your browser options and settings, you may need to download the file for reading. It should be compatible with most versions of Adobe Acrobat Reader, as well as most alternatives.

 Additional content from the 2016 edition of Vol. III should become available soon . . . 

* * * * * * 

Saturday, September 30, 2017

'Heine-IPC': COLOR Phase Contrast... [UPDATE]

Note: For the Original post, see Post of Sept. 24, 2017, immediately below...

One of the more significant justifications for developing something like the current "Heine-IPC System" is the potential for producing high-definition phase contrast images (either with or without color enhancement) using objectives for which no "genuine" phase contrast version is available, or which may never have existed... 

One good example of this is the Nikon 60x/0.85 CF Plan Achromat (non-phase only), used for the next two Heine-IPC images, shown immediately below:


Click on either of the above images for larger views.

The sample image below shows a different color adjustment for the IPC unit, as well as a diatom having greater fine detail in its structure... (Note that the focus in this image is on the fine detail, not on the diatom's overall structure. Click on the image for a larger version.)

Click on any of the above images for larger views.


For discussion of the Nikon IPC system itself, see the post of Feb. 25, 2017, in the Blog Archive. 

Development of the 'Heine-IPC System' is, of course, continuing... 


* * * * * *

Sunday, September 24, 2017

'Heine-IPC': A New COLOR Phase Contrast System?

One incredibly rare bit of microscope technology is the near-legendary Leitz 'Color Heine' phase contrast condenser, shown below, for reference, in comparison with its "common" (non-color) cousin:

Supposedly, only 300 of these very specialized devices were ever made and only a very few are thought to survive today in working condition. Asking prices for working examples today are in the many thousands of dollars – one measure of their uniqueness, and scarcity. Few in microscopy have ever actually seen one, let alone actually used one, and even documentation is almost non-existant. Puplished photos taken through the unit are also extremely rare.

Yet, one benefit of the Color Heine is the knowledge that it is technically possible to achieve Color Phase Contrast using an otherwise ordinary microscope, resulting an underlying desire to achieve this elusive end – somehow!

Now, the simultaneous availability of both an "ordinary" Leitz Heine phase contrast condenser, as well a working example of the not-quite-so-rare Nikon Interference Phase Contrast (IPC) unit, has resulted in an uncommon opportunity to experiment with the combination of these two disparate devices, in the hope of creating a practical and truly flexible 'Color Phase Contrast' System.


The main limitation of the Nikon unit is the matter of finding a condenser with phase rings which acceptably match the phase plates inside the unit – in practice, something much easier said than done... In this light [sic] it was hoped that the Heine condenser could address this problem, resulting in a wider range of optics which could function usefully with the IPC.

As mentioned in a much earlier post, the Nikon IPC was apparently intended to function solely with the old Nikon S-series (short barrel) Achromat objectives, even though much better Nikon optics were readily available, even back then! This odd design limitation seems to have killed the sales of the unit, at least in the US. Still, anone who has one of these systems no doubt has lusted, at least at some time, for the chance to use it with a good Nikon Apo or other fine objective! Thus, the desire to find some practical way to enable this sort of usage, and the subsequent choice of the Leitz Heine condenser as a possible solution... 

But, as the Heine was designed to fit only Leitz microscopes, and the Nikon IPC unit only Nikon  microscopes, a certain amount of "Frankenscope" engineering is to be expected in "marrying" these two separate pieces in the hope of creating a new, viable (and practical) Color Phase Contrast system.

The initial phases of this development effort are now nearing completion and the results should be posted here in the very near future.

Until then, the image set below shows a limited sample of the sort of initial results that may be obtained from this new, "Heine-IPC System", using just ordinary (e.g: non-phase) optics on an unidentified diatom:

Note: Click on the above for larger images. 

As with any development effort of this sort, improvements in both image color and image quality are expected soon... . 

[ NOTE: For the UPDATE to this Post – see Post of Sept.30, 2017.] 

* * * * * *

Friday, June 9, 2017

3D Image Enhancement made Easy – Part IV.

Combining contrast methods

In prior posts we described a simple method, "Radial-3D Masking," for microscope image enhancement with could produce both contrast enhancement and a perception of "3D" (relief effect).

However, while useful on its own, it is also possible to combine this method with at least one other popular contrast method, namely, "Circular Oblique Lighting", ("COL"). This new method has the potential to not only further improve contrast levels in the COL image, but also to add a 3D effect.

Unfortunately, the results of this combination, in some instances, can become a bit excessive. For this reason we will introduce a more moderate version of the Radial-3d Method, termed here the "Diffuse Half-Mask" ("DHM") method.

This is. basically, little more than half of the Radial-3d Method, using only a single diffusion strip, rather than two. It produces results that are a bit less dramatic than the Radial-3d Method, but which may be better-suited for combining with other optical contrast methods. Details of this method, as well as the original Radial-3d Method are shown below:



Examples of just how simple and effective these "combo" contrast methods can be are depicted in the photo set immediately below.

The image set on the left depicts increasing levels of "3D" effect, beginning with 'Brightfield' (no 3d enhancement), then 'DHM' (moderate 3D enhancement) and, finally, 'Radial-3D' (full 3D enhancement).

The image set on the right depicts the same series, but now in combination with COL.

Click anywhere on the above image for larger versions. 

In general, these methods appear to be most effective when applied to subjects which exhibit fine structural detail. Still, they may also be useful with less demanding specimens, as shown in the next photo set:  

Click anywhere on the above image for larger versions. 

Note that when the image contrast is already high (e.g: Phase Contrast) additional contrast enhancement using these methods is likely to be rather limited, if at all. 

In any case, thoughtful experimentation is highly recommended! 



* * * * * 



Tuesday, May 9, 2017

3D Image Enhancement made EASY – Part III.

Comparing Simple Contrast Methods – cont'd.

Part I (April 25th.) of this series introduced a new method of image enhancement (simple '3D') and gave examples of its use.

Part II (May 3rd.) offered further examples of results using this method, particularly as compared to Brightfield and COL.

Part III continues this effort with examples at higher magnification and higher resolution.

Now, in casual microscopy, considerable time is often spent using the 40x ("high dry") objective. This lens offers the combined advantages of reasonably high magnification and resolution, decent working distance, and ease-of use. Also, almost every standard microscope has one. Further, more than 90% of what maybe seen (at high magnification) with Transmitted Light Microscopy may be seen using this type of lens. So, it seems only proper that we should determine just how well the 3D Mask method works with this lens…

In the first set, below, we compare results obtained using Brightfield with those using the Radial 3D mask method. This  set shows the same diatom photographed using each of these methods, with the results adjusted to approximate the actual visual appearance of the object. (If anything, these images understate the advantages of the 3D method, in part due to loss of image quality due to the use of the JPEG image format during image processing.)

Click anywhere on the above image for larger versions. 

Note that the measured width of diatom used in these photo is approximately 21 microns, which results in a calculated 'dot spacing' of about 1.0 microns. As this is reasonably within the resolution capability of the NA 0.70 objective, the performance of the objective itself should not be a limiting factor in these tests.

Not apparent in the photo set is the slight loss in overall image brightness associated with the 3D mask. However, this loss is a small penalty to pay for increased image contrast and resolution.

Radial 3D versus 'COL' – more surprises? 

In the second set, below, we compare the Radial 3D mask method with COL, a currently popular alternative method of contrast enhancement. Once again, the relative levels of image brightness are not preserved in these images, but here, COL typically suffers a much greater loss of overall brightness (typ. 3 to 4 times greater) than does the 3D mask method.

Click anywhere on the above image for larger versions. 

Here the 3D method appears to be at a disadvantage, at least initially, but only because the Condenser Iris was fully open (e.g: 100%).

However, as shown in the third photo set (below), this limitation is easily overcome by simply reducing the Iris opening.  This results in a sort of "variable contrast" mode, where the overall image contrast is readily controllable by means of the Condenser Iris. For Iris openings down to about 60%, there is very little loss in resolution, while even smaller openings (down to about 40-50%) may be used to achieve further increases in image contrast.

Click anywhere on the above image set for larger versions. 

Note that the COL method has no equivalent mode!

With COL results are fixed, as determined by the annulus diameter and opening width. To adjust contrast with COL either the entire Iris must be exchanged or a variable condenser, such as the scarce (and costly) Leitz 'Heine' Condenser, must be used. (Note that the Heine condenser will typically fit only a few older microscopes, whereas the Radial 3D mask method may be used on nearly any microscope equipped with a standard Condenser!)

Finally, remember that, with COL, usually the entire condenser annulus (or the Heine condenser setup) must be changed with every change of objective, while, with the Radial 3D mask method, only a simple Iris "tweak" is all that is typically be needed, if at all.

Next, in Part IV of this series, we will explore some of the unique possibilities for even greater image enhancement using the Radial 3D mask method…


* * * * *

Wednesday, May 3, 2017

3D Image Enhancement made EASY – Part II.

Comparing Simple Contrast Methods

A recent post (April 25, below) has revealed a very simple method of optical contrast enhancement, "Radial 3D Effect", which also adds a measure of 3D-like effect to an overall contrast improvement.. The method is very easy to implement and to use, functioning with a wide range of common objectives and yet requiring no special adjustments with objective changes.


Yet, in spite of these these and other operational advantages (described below), the basic question remains, "Just how well does this new method work?"

In this post we begin to address that question, starting with a direct comparison of images from this new method with those from two common alternative methods: (a) Simple Brightfield, and (b) Circular Oblique Lighting (or, COL). (These other methods also share the traits of simplicity, ease-of-use, and of not requiring any special objectives.)

So, how do these methods actually compare? 

To see, we can begin by examining the image set below… 

Click anywhere on the above image set for larger versions. 

The top image is in Brightfield mode, with illumination by the Kohler Method, with the Condenser Iris set to about 100% of the full objective aperture. This is to serve as the "Reference" image. It reveals a reasonable amount of detail but one could hope for greater contrast. Also, the image appears "flat," revealing little of the object surface texture.

The middle image is basically identical, but with the addition of the Radial "3D" Effect mask discussed earlier. Note that this image shows not only increased object contrast and detail, but also reveals object surface contours, especially evident in the specimen on the left.

The final image was made by replacing the "3D" mask with a standard Condenser phase ring (annulus) to produce COL contrast. Note that here there is also increased contrast (relative to Brightfield), but the "3D" effect seen in the middle image is absent.  However, much unlike the Radial 3D Mask method, image results with COL can be quite dependent upon the exact choice of annulus, as well as 'annulus-specimen' matching. Thus, with COL, each objective potentially requires using a different annulus. (The 'Radial 3D Mask' technique has no such sensitivities.)

One important factor, not shown by the above images, is the difference in overall image brightness which occurs with each of these methods.

Brightfield, of course, offers the highest image brightness level, with the Radial '3D' Mask method running second with somewhat less than half that level (depending on the exact diffusion material used). The COL method, however, is far behind this with overall brightness at 15% or lower, depending upon the size and width of the Condenser annulus selected. (Note that some specially-made COL rings may support slightly higher overall image brightness levels.)

Condenser iris Effects

Both Brightfield and Radial 3D methods also support a basic level of user control over "depth-of-focus" in the specimen plane, simply by adjusting the Condenser Iris opening. Reducing the opening, even by a small amount (e.g: from 100% to 80%) can result in a significant increase in not only depth-of-focus, but also in overall image contrast. These effects are depicted in the image set  below:

Click anywhere on the above image set for larger versions. 

As expected, reducing the Condenser Iris opening in either Brightfield or 3D mode provides a slight increase in image contrast, but in the 3D mode this more significantly enhances the apparent depth-of-focus for the specimen. In general, Iris openings from 100 percent open, down to 50 or 60 percent open, can prove useful. At less than about 50% open, image resolution can begin to suffer noticeably.  

Unfortunately, the COL method (described above) does not directly support such control – with COL the only recourse is to switch to using a smaller diameter annulus, which often can have unpredictable and undesirable effects on the overall appearance of the specimen. 

Be aware that the image set presented above is not intended as definitive basis for comparing these methods, but merely as a basic indication of the results produced by each method. More precise imaging techniques for these three methods, as well as for some additional methods, will be needed to permit extending this evaluation to a more definitive level. 

Note that the above images are limited by minor variations in focus between modes, as well as a slight residual camera motion which may obscure finer detail. Both these issues will be addressed in the test setup before any additional comparison photos are produced.

This comparison will continue is a subsequent post, or two…

* * * * * *